System controller pump 12V, microprocessor, custom

    

Electronic pump control box 12V, microprocessor ARM 8-bit 16 MHz.

To operate the pump to different plans, depending on the required load.

Input: 0 to 5 V signal. default parameters set for a signal box (accelerator) Butterfly.

Output: command of proportional pump by power transistor. Capacity 20 a.

States: Shutdown, standby, market normal, full charge.
Gradual variation of the plan to pump when the state changes.

Durations and cyclical reports Eve, walking, normal and full customizable.
Pre-programmed by default for pumps provided in sections pumps to water.

Cyclical reports of default operation:
Market: 100%
Normal: 50%
Eve: 12%
Cooling (if market exceeded max time): 25%
Stop: 0%

By default, posted times on vehicle turbo fuel road use:
Watch: 30 seconds
minimum market: 5s
maximum market: 120 s
cooling pump (if maximum market) exceeded: 120 s

Default thresholds of input for triggering of the States:
Low threshold: 15%
High threshold: 54%

Examples of logic:
  • standby signal if < low threshold
  • start-up if signal > upper threshold.
  • variation proportional if the signal is located between low threshold and high threshold
  • minimum duration of contract if signal > upper threshold
  • etc.

Example of application: command pump of heat exchanger on turbo engine, by the signal available at the butterfly knob.

Product design and algorithm by ATD Performance. Possibility of development specific to the application.